Concrete Chloride Ion Diffusion Coefficient Tester—RCM Type
Contact Info
- Add:天津市武清区京滨工业园丰元道1号, Zip: 301739
- Contact: 王晓飞
- Tel:17695407260
- Email:cabr17@163.com
Other Products
Product Usage
Used to determine the chloride ion migration coefficient in concrete through non-steady-state migration testing to evaluate the chloride ion penetration resistance of concrete.
Execution Standards
1. "Standard for Test Methods of Long-Term Performance and Durability of Ordinary Concrete" GB/T50082-2009;
2. "Guide for Durability Design and Construction of Concrete Structures" CCES01–
3. "Code for Durability Design of Railway Concrete Structures" TB10005-2010;
4. "Code for Durability Design of Concrete Structures" GB/T50476-2008;
5. "Technical Specification for Anti-Corrosion of Concrete Structures in Highway Engineering" JTG/B07;
6. "Test Code for Hydraulic Concrete" SL352-2006;
7. "Chloride Ion Diffusion Coefficient Tester for Concrete" JG/T262-2009.
Technical Parameters
1. ※ Capable of performing four types of tests: national standard RCM test, Ministry of Transport RCM test, constant current, and constant voltage, truly achieving multi-functionality with one machine;
2. Test channels: 1 to 6 channels, each independent;
3. Temperature accuracy: ≤0.1°C;
4. Input voltage: AC110V/AC220V, dual voltage input;
5. Output voltage: 0~60.0V adjustable;
6. Voltage accuracy: <0.1 V;
7. Voltage resolution: 0.01V;
8. Current accuracy: <0.1 mA, utilizing advanced digital balanced bridge technology, maximum test current
9. ※ Current resolution: 0.01mA;
10. Maximum test current: 650mA;
11. Acquisition interval: 1~100 minutes adjustable;
12. Control method: color touch screen;
13. Storage capacity: supports external storage drives;
14. Maximum records per test: over 30,000 entries;
15. ※ Equipped with new testing fixtures, capable of testing both square and circular specimens;
16. Sensors use DB9-type interfaces to avoid poor contact and ensure easy plugging and unplugging;
17. Built-in short-circuit protection with short-circuit alert and auto-recovery functions;
18. ※ Features power-off memory function; automatically resumes previous test after power restoration without manual intervention, with configurable auto-recovery time;
19. Real-time curve display during testing; automatically calculates results after test completion;
20. Automatic data storage, supports
21. ※ Fully automated test control, independent voltage and current control per channel, customizable voltage (current) inputs for each channel, facilitating comparative research experiments;
1. Vacuum chamber range: 0~-900Pa;
2. Sensor accuracy: 1Pa;
3. ※ Control method: LCD intelligent fully automated Chinese instrument control;
4. Long-lasting stainless steel vacuum chamber;
5. ※ Real-time text display of current device status on screen;
6. Dimensions: 550*400mm*750mm;
7. Net weight: approx. 40Kg;
8. ※ Alarms for air leakage, water leakage, and test completion;
9. Adjustable vacuum saturation pressure, vacuum saturation time, immersion time, and corresponding test pressure;
10. Users can enable automatic drainage function in the software to achieve fully automated test completion.
| Industry Category | Measurement-Analysis-Instruments |
|---|---|
| Product Category | |
| Brand: | ZTKJTJ |
| Spec: | RCM型 |
| Stock: | 50 |
| Manufacturer: | |
| Origin: | China / Tianjin / Wuqingqu |